Verbinden | Art.-Nr. | Sicherungsverstärker | Durchschnittlich bei 50 kA/1500 VDC | Leistungsverlust (W) | Zulassungen | |||
A²s Schmelzen | A²t Clearing | 80% | 100% | UL | TÜV | |||
Verschraubt | HCHVT1500-100B-74ES | 100A | 1081 | 4399 | 45 | 57 | ● | ● |
HCHVT1500-125B-74ES | 125A | 1645 | 7849 | 52 | 64 | ● | ● | |
HCHVT1500-160B-74ES | 160A | 3572 | 13160 | 69 | 85 | ● | ● | |
HCHVT1500-200B-74ES | 200A | 4888 | 22090 | 81 | 104 | ● | ● | |
HCHVT1500-250B-74ES | 250A | 9776 | 42300 | 93 | 114 | ● | ● | |
HCHVT1500-315B-74ES | 315A | 19864 | 71440 | 102 | 128 | ● | ● | |
HCHVT1500-350B-74ES | 350A | 27293 | 97435 | 111 | 140 | ● | ● | |
HCHVT1500-400B-74ES | 400A | 35980 | 126652 | 128 | 161 | ● | ● | |
HCHVT1500-450B-74ES | 450A | 51208 | 175802 | 140 | 177 | ● | ● | |
HCHVT1500-500B-74ES | 500A | 69286 | 236492 | 152 | 192 | ● | ● | |
HCHVT1500-550B-74ES | 550A | 86708 | 289098 | 165 | 209 | ● | ● | |
HCHVT1500-630B-74ES | 630A | 122580 | 398997 | 185 | 234 | ● | ● | |
HCHVT1500-700B-74ES | 700A | 169997 | 541567 | 199 | 257 | ● | ● | |
HCHVT1500-800B-74ES | 800A | 263998 | 814912 | 214 | 277 | ● | ● |
Verbinden | Art.-Nr. | Sicherungsverstärker | Durchschnittlich bei 50 kA/1500 VDC | Leistungsverlust (W) | Zulassungen | |||
A²s Schmelzen | A²t Clearing | 80% | 100% | UL | TÜV | |||
Lärm | HCHVT1500-100U-74ES | 100A | 1081 | 4446 | 45 | 57 | ● | ● |
HCHVT1500-125U-74ES | 125A | 1645 | 7933 | 52 | 64 | ● | ● | |
HCHVT1500-160U-74ES | 160A | 3572 | 13300 | 69 | 85 | ● | ● | |
HCHVT1500-200U-74ES | 200A | 4888 | 22325 | 81 | 104 | ● | ● | |
HCHVT1500-250U-74ES | 250A | 9776 | 42750 | 93 | 114 | ● | ● | |
HCHVT1500-315U-74ES | 315A | 19864 | 72200 | 102 | 128 | ● | ● | |
HCHVT1500-350U-74ES | 350A | 27293 | 98471 | 111 | 140 | ● | ● | |
HCHVT1500-400U-74ES | 400A | 35980 | 127999 | 128 | 161 | ● | ● | |
HCHVT1500-500U-74ES | 500A | 69286 | 239035 | 152 | 192 | ● | ● | |
HCHVT1500-630U-74ES | 630A | 122580 | 407578 | 185 | 234 | ● | ● | |
HCHVT1500-700U-74ES | 700A | 169997 | 553214 | 199 | 257 | ● | ● | |
HCHVT1500-800U-74ES | 800A | 263998 | 832437 | 214 | 277 | ● | ● |
Verbinden | Art.-Nr. | Sicherungsverstärker | Durchschnittlich bei 50 kA/1500 VDC | Leistungsverlust (W) | Zulassungen | |||
A²s Schmelzen | A²t Clearing | 80% | 100% | UL | TÜV | |||
Anpassen | HCHVT1500-100K-74ES | 100A | 1081 | 4446 | 45 | 57 | ● | ● |
HCHVT1500-125K-74ES | 125A | 1645 | 7933 | 52 | 64 | ● | ● | |
HCHVT1500-160K-74ES | 160A | 3572 | 13300 | 69 | 85 | ● | ● | |
HCHVT1500-200K-74ES | 200A | 4888 | 22325 | 81 | 104 | ● | ● | |
HCHVT1500-250K-74ES | 250A | 9776 | 42750 | 93 | 114 | ● | ● | |
HCHVT1500-315K-74ES | 315A | 19864 | 72200 | 102 | 128 | ● | ● | |
HCHVT1500-350K-74ES | 350A | 27293 | 98471 | 111 | 140 | ● | ● | |
HCHVT1500-400K-74ES | 400A | 35980 | 127999 | 128 | 161 | ● | ● | |
HCHVT1500-500K-74ES | 500A | 69286 | 241578 | 152 | 192 | ● | ● | |
HCHVT1500-630K-74ES | 630A | 122580 | 407578 | 185 | 234 | ● | ● | |
HCHVT1500-700K-74ES | 700A | 169997 | 553214 | 199 | 257 | ● | ● | |
HCHVT1500-800K-74ES | 800A | 263998 | 832437 | 214 | 277 | ● | ● |
Der Gleichstrom-Kaltwiderstand wird bei <10 % des Nennstroms bei einer Umgebungstemperatur von 25 °C gemessen.